The Orga L1000-856 high intensity flashing white strobe obstacle light complies with FAA type L856 & ICAO Annex 14 Vol.1, Fourth edition - July 2004, Chapter 6 type A high intensity obstacle light.
Application
Marking of aviation hazards, typically structures such as communication towers, broadcast towers, electricity transmission and distribution towers, chimneys, bridges, wind and tall buildings.
Technical data / Characteristics
Operating voltage: 110-230 Vac (±10 %), 50-60 Hz- Power consumption: <150 W average continuous for standard day
- Control: Internal microprocessor based controller for power management, flash character, daylight on/off and failure alarm control
- Alarms: Volt free dry alarm relay contact (2 A) for lamp failure. Further alarms and status information via CIP control unit
- Photocell (Sunswitch): Two internal photocells fitted in the light fixture for automatic day/night control
- Light source / life expectancy: Xenon flash tube, >2 years life. Safe plug fitting
- Lensdiameter / colour: Not applicable / white
- Divergence (beam angle): 120° visibility by 3° vertical divergence (minimum three lights per level for 360° coverage)
- Effective intensity: 270.000 Cd (FAA) or 200.000 Cd (ICAO) white ±25 % in day time mode, 20.000 Cd white ±25 % in twilight mode, 2000 Cd white ±25 % in night time mode
- Flash character: Factory set at 40 fpm (FAA) or 40-60 (ICAO) fpm
- Operating temperature: -55 °C to +55 °C, 95 % relative humidity
- Ingress protection: IP67
Features
- Advanced communication facilities in multiple light systems
- Very high optical efficiency resulting in low power consumption comparing to equivalent products
- Intelligent lamp control technology for maximum lamplife and low power consumption
- Simple latch and tilt lens with safety switch protection, and safe plug lamp unit for simple maintenance
- Low cost cabling scheme
- Stainless steel housing
- Toughened glass window with internal parabolic reflector
- Micro-switch provided to disconnect power on opening of the light fixture, with power connected warning LED
- Two stage overvoltage protection devices
Certificates
- ICAO Annex 14 Vol.1, Fourth edition - July 2004 (compliant)
- FAA AC150/5345-43E
Additional information
- DS - L1000 (E) r4.PDF
Datasheet - L1000-xxx drawing.PDF
Drawing - EG033 L1000-xxx_R01 (BT-A).PDF
EC declaration of conformity