Airport Articles
Subscribe to ArticlesL303-864/865 and L303-885/866: Medium Intensity Red/White Flashing Strobe Obstruction Light
Orga
Category: Aeronautical Obstruction Lights | 01/12/2006 - 14:43:01
Application
Marking of aviation hazards, typically structures such as communication towers, broadcast antennas, electricity transmission and distribution towers, chimneys, bridges, wind turbines and tall buildings.
Technical data / Characteristics
Operating voltage: 110-240 Vac (±10 %), 50-60 Hz- Power consumption: 100 W continuous @40 fpm during daytime, 45 W continuous @40 fpm during nighttime
- Control: Internal microprocessor based controller for power management, flash character, daylight on/off and failure alarm control
- Alarms: Volt free dry alarm relay contact (2 A) for lamp failure. Further alarms and status information via CIP control unit
- Photocell (Sunswitch): Two internal photocells fitted in the light fixture for automatic day/night controlLight
- Source / life expectancy: Xenon flash tube, >2 years life. Safe plug fitting
- Lensdiameter / colour: Precision injection moulded Ø300 mm fresnel lens. UV resistant with hinged opening / white lens with red filter for night operation
- Divergence (beam angle): 360° horizontal, 3° vertical at 50 % peak
- Effective intensity: 20.000 cd white ±25 % in day time mode, 2000 cd red ±25 % in night time mode
- Flash character: Factory preset: 40 fpm, 20-40 (FAA) or 20-60 (ICAO) fpm
- Operating temperature: -55 °C to +55 °C, 95 % relative humidity
- Ingress protection: IP65
Features
- Used as single light or in multiple light systems
- Advanced communication facilities in multiple light systems
- Light weight, omni-directional lights
- Very high optical efficiency resulting in low power consumption comparing to equivalent products
- Intelligent lamp control technology for maximum lamplife and low power consumption
- Simple latch and tilt lens with safety switch protection, and safe plug lamp unit for simple maintenance
- Low cost cabling scheme
- Micro-switch provided to disconnect power on opening of the light fixture, with power connected warning LED
- Over voltage protection devices to protect against lightning discharges
Certificates
- ICAO Annex 14 Vol.1 (compliant)
- FAA AC150/5345-43E
- Dutch CAA approval
- French CAA approval (STNA)
Additional information
- Datasheet L303-864865 & L303-885866 300506 revA.doc
Datasheet - L303-86DUAL drawing.pdf
Drawing - 0IOM - L303-8xx (E) r6b.PDF
Instruction & operation manual - 0EG033 L303-8xx_R03 (BT-A).PDF
EC declaration of conformity